GSM Technology, in addition to making our lives easier with mobile phones, businesses it offers opportunities to keep their costs under control and reduce. GSM With its technology, data has the ability to be transferred without distance recognition. Word the concept of telemetry, the meaning of which is remote monitoring, is wireless, especially GSM technology it is used for data transmission systems.Also Rs485 Ethernet Rs232 SDI12 collect data from its ports, save it and track it remotely.(Protocols : Modbus RTU Modbus TCP/IP CanBus ProfiBus DP SDI12 ASCII)

technical data

- 24-Bit resolution, high sensitivity
- Isolated Channels
- High sampling and recording frequency
- Universal Input; Pt1000, thermocouple types, 0/4-20 mA, 0-10 Vdc, mV, Load cell sensors can be identified according to the request.
- Digital Input channels, Pulse counting, frequency measurement
- Connection of Meteorological Sensors with SDI12 communication (SDI12 Master)
- RS 232 and RS485 ports (Master or Slave use)
- ASCII or Modbus protocol support on Serial Ports (programming on demand)
- 12...Possibility of Battery or solar panel power supply with 24 Vdc Supply December
- Low energy consumption feature with sleep mode
- User-defined wake-up and recording feature
- Built-in 4 GB or 16 GB memory options (billions of recordings)
- Recording at microsecond frequencies (high-speed sampling and recording feature)
- CAN-Bus Master port (separate reading and recording of sensors with CAN-Bus output)
- Reading and recording data from Siemens S7 PLCs with PROFIBUS DP Master Port, data collection applications
- Ability to transfer AI channel information to Siemens S7 PLCs with PROFIBUS DP Slave port
- Data Acquisition of sensors or sensors with Rs485 Modbus output with Rs485 Modbus Master Reading, saving modules, collecting data
- Ability to transfer AI channel information to other systems with the Rs485 Modbus Slave function
- ASCII or Modbus protocol support on Serial Ports (programming on demand)
- Modbus TCP/IP Master/Slave functions on the Ethernet port
- PC-independent recording feature on the device (datalogger)
- User-defined wake-up and recording feature
- Creating virtual channels, formula entries
- Control of Digital Outputs (on-off, PID control features)
- Recording of images (images) with a webcam (USB) connection
- Computer connection via USB, Ethernet, 4G GSM, WLAN Wireless